The Harvia Hidden Heater fits behind the sauna bench. Its stainless-steel body supports a clean interior layout in home and commercial saunas.
All models require a compatible separate control unit. Check the exact model instructions before finalising the layout.
First, confirm the room dimensions and wall materials. Then review the space behind the bench, required clearances and access for servicing. Keep ventilation paths clear according to the manufacturer's instructions.
Your installer should also check the electrical supply and control compatibility. The room range alone does not confirm that a heater suits every construction.
Send the heater code, quantity and delivery country. Include the bench drawing and any existing controller details. We can review the proposed package and confirm the quoted items before you order.
Browse our sauna accessories or learn about ROC Sauna Solution. For current model documentation, consult Harvia.
Certification coverage, electrical version and included accessories are confirmed for the exact model and destination market. Genuine Harvia equipment retains its original branding; OEM and private-label options apply to ROC's own product line.
Detailed performance data for all available models in the Harvia Hidden Heater Behind-Bench Electric Sauna Heater series.
| Specification | HH3 | HH6 | HH9 | HH12 |
|---|---|---|---|---|
| Model | HH3 | HH6 | HH9 | HH12 |
| Power (KW) | 2.9 | 6.0 | 9.0 | 12.0 |
| Room Volume (m³) | 2-4 | 6-10 | 10-14 | 12-17 |
| Stone Weight (KG) ø 5-10cm | 12 | 15 | 15 | 15 |
| 400V 3N~cable (mm²) Connect to controller | 5x1.5 | 5x1.5 | 5x2.5 | 5x4.0 |
| 400V 3N~cable (mm²) To sauna heater | 5x1.5 | 5x1.5 | 5x2.5 | 5x2.5 |
| 400V 3N~cable (mm²) To junction box | 5x1.5 | 5x1.5 | 5x2.5 | 5x2.5 |
| 400V 3N~ Fuse (A) | 3x10 | 3x10 | 3x16 | 3x20 |
| Minimum safe distance: A_min (mm) | 75 | 75 | 75 | 90 |
| Minimum safe distance: B_min (mm) | 75 | 75 | 90 | 120 |
| Wire connected to the sensor mm² | 4x0.25 | 4x0.25 | 4x0.25 | 4x0.25 |
Interested in the Harvia Hidden Heater Behind-Bench Electric Sauna Heater? Fill in the form below and our team will respond within 24 hours with pricing, MOQ details and lead time.
Published ratings: HH3 (2.9 kW) suits 2-4 m3 rooms; HH6 (6.0 kW) suits 6-10 m3 rooms; HH9 (9.0 kW) suits 10-14 m3 rooms; HH12 (12.0 kW) suits 12-17 m3 rooms. Pick the model whose range covers your room volume.
The published difference is capacity: HH3 is 2.9 kW for 2-4 m3 rooms; HH6 is 6.0 kW for 6-10 m3 rooms; HH9 is 9.0 kW for 10-14 m3 rooms; HH12 is 12.0 kW for 12-17 m3 rooms. Measure your sauna in cubic metres and pick the model whose range covers it. If your room falls in an overlap zone, send your exact room details via the quote form and we will size it for you.
Published minimum safe distances in mm: to the side (A_min) HH3 = 75; HH6 = 75; HH9 = 75; HH12 = 90; to the ceiling direction (B_min) HH3 = 75; HH6 = 75; HH9 = 90; HH12 = 120. The full installation data is in the specification table above.
Yes. As an authorized Harvia distributor we supply this heater to hotels, spas and dealers. For project pricing, reach out via the quote form on this page and our team will help you directly.